Output elements
WARNING | |
Secure moving parts against ejection Make sure there are no moving parts on or in the machine during operation. Feather keys [+] are only secured during transport. Unsecured parts can be ejected from the machine during operation and cause serious or fatal injuries. |
Notice | |
Protect distributed servo drive from impermissible stresses Do not bend components during transport or handling and do not change any insulation distances. Avoid hard shocks to the shaft end, the ball bearings or the feedback system. Furthermore, note vibration qualities and vibration resistance. If necessary, provide additional support for the distributed servo drive. An impermissible load on the components can have a negative effect on the performance of the distributed servo drive. Impacts on the motor shaft impair the concentricity of the distributed servo drive. |
Notice | |
Overheating hazard The thermal connection of the motor flange determines the power loss. An inadequate thermal connection can lead to the motor overheating, which can have a detrimental effect on the operational safety and service life of the motor.
|