Mounting

WARNING

Burn injuries caused by hot components

Hot components can cause severe burns to body parts and limbs.

  • Only handle hot output elements, such as couplings or pulleys, with special thermal gloves
  • Avoid prolonged contact with hot components

Notice

Damage caused by improper installation

Offset during the installation of the drive components leads to excessive vibrations and damage to the ball bearings and coupling.

  • Do not mount the drive elements offset
  • Place the drive elements centered and straight on the motor shaft
►Warm up the output element according to manufacturer's instructions
►Remove the protective cap
►Degrease and clean the motor shaft
►Remove the output element from the oven and transport it to the workspace
►Place output element [1] centered and straight on the motor shaft [2]
►Insert washer [3] with screw [4] of strength class 8.8 and nut [5] into the locking thread [6] of the motor shaft
►Tighten nut [5]

The output element is pulled onto the motor shaft by the nut.