Long-term storage

Notice

Product damage due to storage

Exceeding the specified maximum storage time can lead to a change in the properties of the components used in the distributed servo drive system and may damage them during operation.

  • Observe the maximum storage time.
  • Keep the storage room vibration-free.
  • Check components for proper condition every six months.

Notice

Product damage due to condensation

Condensation can lead to damage during subsequent operation or to rust formation.

  • Keep the ambient temperature constant
  • Avoid solar radiation
  • Avoid high air humidity

You have the possibility to store the components of the distributed servo drive system over a short or long period. For storage we always recommend the original packaging. Adhere to the conditions specified in the chapter: Transport and storage.

Exceeding the specified maximum storage time can lead to a change in the properties of the components used in the distributed servo drive system and may damage them during operation. Damage to the drive or maintenance work not carried out will affect the service life of the installed components and parts. Condensation can lead to damage during subsequent operation or to rust formation. Prevent the formation of condensation.

AMP80xx, AMP85xx

maximum storage time: 2 years

Exceeding the specified maximum storage time can lead to a change in the properties of the lubricant used and may damage the drive during operation.

AMP8620, AMP8805, AX883x

Notice

Limited functionality due to unformed capacitors

The dielectric in the DC link capacitors decreases over a very long storage period and the capacitors lose their forming. This can lead to considerable functional restrictions and even a shortened service life of the device.

  • If the storage period exceeds 5 years, form the capacitors

maximum storage time: 5 years

Exceeding the specified maximum storage time can lead to a change in the properties of the components used in the distributed servo drive system and may damage them during operation.