Industrial PC

Fieldbus Components

Drive Technology


Servo drive


Distributed servo drives


Rotary servomotors


Translatory servomotors


Planetary gears


Transport systems


Compact drive technology


Accessories


Software



TE5910 | TC3 Motion Designer - Quick commissioning guide



AX8000 | Multi-axis servo system - Function description



AX5000 | Digital compact servo drives - Function description



AX5000 | Digital compact servo drives - IDN-Description



AX5000 | Digital compact servo drives - Diagnostic Messages



AX5000 EMC-Manual - Version 1.1



AX5000 Tuning-Guide - Version 1.0



AX8xxx | Axis module - Diagnostic messages



AX8xxx | Axis module - Object dictionary



AX86x0 | Power supply module - Object dictionary



AX86x0 | Power supply module - Diagnostic messages



AX8820 | Universal regenerative unit - Diagnostic messages



AX8820 | Universal regenerative unit - Object Dictionary



AMP8000 | Distributed servo drives - Diagnostic messages




Standard-Messages




Diagmessages of DeviceMainSlot




Diagmessages of SafetySlot




Diagmessages of DeviceDebugSlot




Diagmessages of AxisMainSlot




Diagmessages of InterpolatorSlot




Diagmessages of PositionControlSlot




Diagmessages of VelocityControlSlot




Diagmessages of BiquadFilterSlot




Diagmessages of TorqueControlSlot




Diagmessages of FeedbackSlot





7320, HpfDsl: Encoder error (position invalid), Id=0xXX, Arg=0xXX





7380, HpfDsl: Encoder start sequence failed, Id=0xXX, Arg=0xXX





7381, HpfDsl: Encoder shutdown failed, Id=0xXX, Arg=0xXX





7382, HpfDsl: Parameter access error, Id=0xXX, Cmd=II, RID=0xXX, Offset=II, Len=II, LongMsgErrorCode=0xXX





7383, HpfDsl: Internal error, Id=0xXX, Arg=0xXX





7384, HpfDsl: Cyclic monitoring error, Id=0xXX, Arg=0xXX





7385, HpfDsl: Encoder file processing, Id=0xXX, WarnArg=0xXX





7386, HpfDsl: Found no encoder (No link to an encoder)!





7387, HpfDsl: The encoder doesn't meet the specified policies. Resolutionpolicy=II [Encoder=II, Requirement=II], Rangepolicy=II [Encoder=II, Requirement=II]





7388, HpfDsl: Encoder power off (triggered from SafeCu), Id=0xXX, Arg=0xXX





7389, HpfDsl: Encoder interface resistance check failed. Measured resistance is too low! R=II Ohm





738A, Loaded fpga is not verified.





738B, HpfDsl: Internal warning! The error inducer is available.





738C, HpfDsl: Encoder seems to be offline for UU cycles. (InternalDbg: UU)





738D, HpfDsl: Invalid encoder parameter, see SubIdx UU





738E, HpfDsl: Encoder file processing error, FileId=0xXX, Arg=0xXX





738F, HpfDsl: SafeCU monitored encoder status flag is set! The next fault reset triggers an encoder restart. EncST7..4=0xXX, EncST3..0=0xXX





7390, HpfDsl: Status dump, Encoder Status after IIms: Summary=0xXX, Regs 7..4=0xXX, Regs 3..0=0xXX





7391, HpfDsl: Status dump, Max occured position deviation=UU mdeg





7392, HpfDsl: Status dump, Error counter VPOS=UU, ACC=UU, VRT=UU, POS=UU, LINK=UU, Encoding=UU





7393, HpfDsl: A safety error condition is blocking the encoder voltage.





7394, HpfDsl: An overload or an open load state is detected on the 2WireInterface.





FFFF, HpfDsl: Internal Error, Additional Errorcode 0xXX




Diagmessages of MotorSlot




Diagmessages of AxisDebugSlot



AMP8000 | Distributed servo drives - Object Dictionary