Reduce air gap

Notice

Air gap must be at least 0.7 mm

To check the air gap, the mover must be on the guide rail. The air gap must be at least 0.7 mm.

If the air gap is too small, damage to the mover and the system may result.

Reduce air gap 1:
►Loosen set screw [1]

Rotation

Changing the air gap [mm]

1/4

0.1

Reduce air gap 2:
►Tighten set screw [1] on the opposite side accordingly
►Check the air gap

If the air gap is not yet set correctly:

►Loosen and tighten the set screws again

OR

►Increasing the air gap

Further information can be found in chapter Increasing the air gap.