InfoBars

InfoBars 1:
►Expand InfoBars
►Click … from InfoBars
InfoBars 2:

The dialog box XtsView | InfoBars opens.

►Click on Add

An XtsInfoBar is added. The properties of the XtsInfoBar can be set in the Properties area.

InfoBars 3:
►Expand Colors

The adjustment range is displayed.

Further information can be found in chapter Colors.

InfoBars 4:
►Expand General
►Enter values in the input fields PartIndex, PartStartPosition and PartEndPosition
InfoBars 5:
►Expand Layout
►Enter values in the input fields InfoBarThickness and InfoBarDisplacement
►Activate the checkbox Visible to show the InfoBar

OR

►Deactivate the checkbox Visible to hide the InfoBar
►Enter a value in the input field zIndex
InfoBars 6:
►Expand Marker
►Click … from Marker
InfoBars 7:

The dialog box Marker opens.

►Click on Add

An XtsInfoBarMarker is added. The properties of the XtsInfoBarMarker can be set in the Properties area.

InfoBars 8:
►Expand Colors

The adjustment range is displayed.

Further information can be found in chapter Colors.

InfoBars 9:
►Expand General
►Enter a value in the input field InfoBarPosition
InfoBars 10:
►Expand Layout
►Select the marker type from the drop-down menu MarkerType
InfoBars 11:
►Enter values in the input fields MarkerThickness, MarkerSize and zIndex

Further information can be found in chapter zIndex.

InfoBars 12:
►Expand Text
►Enter a text in the input field MarkerText

OR

►Click on the button to open the Multiline editor

Further information can be found in chapter Link formula.

►Enter a value in the input field TextDisplacement
►Click ... from TextOptions

The dialog box TextOptions opens.

Further information can be found in chapter TextOptionsGeneral settings.

InfoBars 13:
►Confirm with OK

The dialog box Marker closes.

InfoBars 14:
►Expand Text
►Enter a text in the input field InfoBarText

OR

►Click on the button to open the Multiline editor
►Click on a button at TextPlacement to select the alignment of the text
►Enter a value in the input field TextDisplacement
►Click ... from TextOptions

The dialog box TextOptions opens.

Further information can be found in chapter TextOptionsGeneral settings.

InfoBars 15:
►Confirm with OK

The dialog box XtsInfoBars closes.

The table shows the default parameter settings for the InfoBars properties:

Property

Explanation

Default setting

InfoBars

 

…

InfoBars 16: Colors

 

 

  • InfoBarColor

Color that can be defined for the InfoBar

#FF00000

InfoBars 17: General

 

 

  • PartIndex

 

0

  • PartStartPosition

Point at which the part begins

10

  • PartEndPosition

Point at which the part ends

200

InfoBars 18: Layout

 

 

  • InfoBarThickness

InfoBar thickness

8

  • InfoBarDisplacement

Offset of the text

100

  • Visible

Visibility of the tool

True

  • zIndex

Z-position, position of the visual element and information about the update of the visual element

1000

InfoBars 19: Marker

 

 

Marker

 

…

  • MarkerColor

Color that can be defined for the marker

#FF000000

  • InfoBarPosition

Position of the InfoBar

100

  • MarkerType

Selection of the marker type

Diamond

   • None

No marker

–

   • Diamond

Diamond

–

   • Tick

Tick

–

  • MarkerThickness

Marker thickness

5

  • MarkerSize

Marker size

25

  • zIndex

Z-position, position of the visual element and information about the update of the visual element

1001

  • MarkerText

Text displayed with the marker

–

  • TextDisplacement

Offset of the text

15

  • TextOptions

Properties of the text design

…

InfoBars 20: Text

 

 

  • InfoBarText

Text that is displayed in the InfoBar

–

  • TextPlacement

Text alignment

Left-justified

   • InfoBars 21: left-justified

Left aligned

–

   • InfoBars 22: centered

Centered

–

   • InfoBars 23: right-justified

Right aligned

–

  • TextDisplacement

Offset of the text

15

  • TextOptions

Properties of the text design

…