Mover
| |
Do not position the mover until the electrical installation has been completed The movers may only be positioned once part 1 of the mechanical installation and the electrical installation have been completed. Perform a tile system test before positioning the movers. Failure to do so may result in serious injury to fingers from crushing and to eyes from splinters. Wear safety goggles and gloves The movers can have strong magnetic attraction to each other or other metallic objects. Splinters can form if magnets collide. Failure to do so may result in serious injury to fingers and eyes. Remove each mover individually from the box If you take two movers out of the box and the distance between the movers is too small, the movers can attract each other. If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result. Do not reach under the mover with your fingers When carrying a mover or positioning it on the system, do not reach under the mover with your fingers. Failure to do so can result in severe crushing and injury to fingers. Movers contain strong permanent magnets The permanent magnets are arranged in so-called Halbach arrays, which ensure that the magnetic field on the underside of the mover is significantly stronger than on the upper side of the mover. The field of the permanent magnets is present even when the power supply is switched off. If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result. |