PLC
PLC project
Call: Select the PLC project at System Manager level, i.e. at the upper node in the project tree, and open the Properties window.
| Name | Description | Supported since | 
| Defines | The compiler definitions listed on the Project tab are only saved for the active project variant or group. Note: Compiler definitions are not generally transferred by the System Manager to stand-alone PLC projects, as in this case only the TMC file of an already compiled PLC project is added in the System Manager. | Build 4024.0 | 
| Disable | The PLC project is only disabled for the active project variant or group. | Build 4024.0 | 
PLC instance
Call: Select the PLC instance in the project tree and open the Properties window.
| Name | Description | Supported since | 
| Disable | The PLC instance is only disabled for the active project variant or group. | Build 4024.0 | 
| Parameter | The initial values of the variables listed on the Symbol Initialization tab can be enabled for the variant management. You can choose between three options: 
 Note: If you switch from None to Selected, all parameters are initially disabled for the variant management. You can now enable the desired parameters. If you switch from All to Selected on the other hand, all parameters are already enabled. You can only disable the undesired parameters for the variant management. | Build 4024.0 | 
Stand-alone PLC project
Call: Select the stand-alone PLC project at System Manager level, i.e. at the upper node in the project tree, and open it.
| Name | Description | Supported since | 
| Disable | The stand-alone PLC project is only disabled for the active project variant or group. | Build 4024.0 | 
| Variant | The variant of the stand-alone PLC project selected on the Project tab is only saved for the active project variant or group. Info: If the entry <matching variant> is selected in the drop-down menu, the variant of the stand-alone PLC project with the same name as the active variant is automatically selected. | Build 4024.17 | 
See also:
- Attribute 'TcInitSymbol'
- Workflow: Enabling a setting
- Concept: Concept