UA_Connect

This function block establishes an OPC UA Remote connection to another OPC UA Server, which is specified via ServerUrl and SessionConnectInfo. The function block returns a connection handle that can be used for other function blocks, such as UA_Read.
 Inputs
VAR_INPUT
    Execute            : BOOL;
    ServerUrl          : STRING(MAX_STRING_LENGTH);
    SessionConnectInfo : ST_UASessionConnectInfo;     
    Timeout            : TIME := DEFAULT_ADS_TIMEOUT; 
END_VARName  | Type  | Description  | 
|---|---|---|
Execute  | BOOL  | The command is triggered by a rising edge at this input.  | 
ServerUrl  | STRING(MAX_STRING_LENGTH)  | OPC UA Server URL, i.e. 'opc.tcp://172.16.3.207:4840' or 'opc.tcp://CX_0193BF:4840'.  | 
SessionConnectInfo  | ST_UASessionConnectInfo  | Connection information (see ST_UASessionConnectInfo)  | 
Timeout  | TIME  | Time until the function is aborted. DEFAULT_ADS_TIMEOUT is a global constant, set to 5 seconds. The value must be set to match the ST_UASessionConnectInfo.tConnectionTimeout. The rule of thumb is: ADS Timeout > 2 * ConnectionTimeout.  | 
 Outputs
VAR_OUTPUT
    ConnectionHdl : DWORD;
    Done          : BOOL;
    Busy          : BOOL;
    Error         : BOOL;
    ErrorID       : DWORD;
END_VAR Name  | Type  | Description  | 
|---|---|---|
ConnectionHdl  | DWORD  | OPC UA connection handle.  | 
Done  | BOOL  | Switches to TRUE if the function block was executed successfully.  | 
Busy  | BOOL  | TRUE until the function block has executed a command, at the most for the duration of the "Timeout" at the input. The inputs accept no new command as long as Busy = TRUE. It is not the connection time that is monitored but the reception time.  | 
Error  | BOOL  | Switches to TRUE if an error occurs while executing a command. The command-specific error code is included in ErrorID.  | 
ErrorID  | DWORD  | Contains the command-specific error code of the most recently executed command.  | 
Requirements
Development environment  | Target platform  | PLC libraries to include  | 
|---|---|---|
TwinCAT 3.1  | Win32, Win64, CE-X86, CE-Arm®  | Tc3_PLCopen_OpcUa  |