ST_UASessionConnectInfo
Syntax
TYPE ST_UASessionConnectInfo:
STRUCT
    sApplicationName     : STRING(MAX_STRING_LENGTH);
    eSecurityMode        : E_UASecurityMsgMode;
    eSecurityPolicyUri   : E_UASecurityPolicy;
    eTransportProfileUri : E_UATransportProfile;
    tSessionTimeout      : TIME;
    tConnectTimeout      : TIME;
END_STRUCT
END_TYPEValues
Name  | Description  | 
|---|---|
sApplicationUri (obsolete)  | Application Uri maximum string length 255.   | 
sApplicationName  | Application name with a maximum string length of 255.  | 
eSecurityMode  | Security message mode. For available modes see E_UASecurityMsgMode.  | 
eSecurityPolicyUri  | Security policy Uri. For available security policy Uri see E_UASecurityPolicy.  | 
eTransportProfileUri  | Transport profile Uri. For available transport profile Uri see E_UATransportProfile;  | 
stUserIdentTokenType  | Structure with authentication data for logging on to the OPC UA Server. Full description under ST_UAUserIdentityTokenType.  | 
tSessionTimeout  | Session timeout value.  | 
tConnectTimeout  | Value for the connection timeout. This must be set at the UA_Connect function block to match the ADS timeout. The rule of thumb is: ADS Timeout > 2 * ConnectionTimeout.  | 
Requirements
Development environment  | Target platform  | PLC libraries to include  | 
|---|---|---|
TwinCAT 3.1  | Win32, Win64, CE-X86, CE-Arm®  | Tc3_PLCopen_OpcUa  |