FB_MdAnalogValue
![FB_MdAnalogValue 1:](Images/jpg/17196909835__Web.jpg)
This machine data component contains parameters that are relevant for analog scaled I/Os.
Syntax:
FUNCTION_BLOCK FB_MdAnalogValue EXTENDS FB_MdBaseComponent
Machine data
Index (Identifier) | Parameter | PLC storage location |
---|---|---|
| ScalingRawMin | |
| ScalingRawMax | |
| ScalingValueMin | |
| ScalingValueMax | |
| ScalingElectricalMin | |
| ScalingElectricalMax | |
| UnitValue (16 indices) | |
| UnitElectrical (16 indices) | |
| LimitL | |
| LimitLL | |
| LimitH | |
| LimitHH |
Properties
Name | Type | Access | Initial value | Description |
---|---|---|---|---|
Connected | BOOL | Get | FALSE | Component is connected to its dependencies (except for the MD container). |
FB_MdAnalogValue | ||||
ConnectedMonitoring | BOOL | Get | FALSE | Component is connected to a Monitoring class to save additional parameters.
|
FB_MdBaseComponent | ||||
LinkedContainer | Get | NULL | Points to the container to which the component was appended. | |
Tc3_PlasticFunctions.FB_MdComponent | ||||
Further characteristics | <> | <> | <> | Implemented by FB_MdComponent |
Methods
Name | Description |
---|---|
AddNextComponent() | Adds the subsequent component to the component (list). |
FB_MdAnalogValue | |
Connect( | Connects the component with the necessary dependencies. |
ConnectMonitoring( | Connects the component to other optional dependencies. |
FB_MdBaseComponent | |
[ | Used with inheriting classes to initialize the encoding offset after |
[ | Used with the inheriting class to initialize the encoding offset. |
[ | Simplified method for reading a text-based machine data parameter. This method is used within the MdNextParameter(...) Callback method. |
[ | Simplified method for writing a text-based machine data parameter. This method is used within the MdSetParameter(...) Callback method. |
Tc3_PlasticFunctions.FB_MdComponent | |
Other methods | Implemented by FB_MdComponent. |
Event-driven methods (callback methods)
Name | Description |
---|---|
Container call for saving the parameters in a file, implemented by FB_MdComponent. | |
Container call for loading the parameters into the runtime, implemented by FB_MdComponent. |
Interfaces
Type | Description |
---|---|
I_MdComponent | Standard interface on FB_MdComponent |
I_MdAnalogValue | Standard interface on FB_MdAnalogValue. |
I_MdBaseComponent | Standard interface on FB_MdBaseComponent |
Further interfaces | Implemented by FB_MdComponent |
Requirements
Development environment | Target platform | PLC libraries to include |
---|---|---|
TwinCAT v3.1.4024.35 | PC or CX (x64, x86) | Tc3_PlasticBaseApplication (>= v3.12.5.0) |