ExternalHydAxisLibRef

This class represents a standard hydraulic axis of the Tc2_Hydraulic library (without using an FB_AxisHydraulicBase). This allows standard hydraulic axes and TF8560-based hydraulic axes to communicate with the PlcMcManager in one application.
Syntax:
FUNCTION_BLOCK FB_ExternalHydAxisLibRef
VAR_INPUT
stAxisRef : AXIS_REF_BkPlcMc;
END_VAR
Inputs
Name | Type | Description |
|---|---|---|
stAxisRef | Reference to the hydraulic axis. |
Properties
Name | Type | Access | Description |
|---|---|---|---|
NextHydAxis | I_ExternalHydAxisLibRef | Get, Set | Interface to another hydraulic axis. |
NextHydAxisChainlength | INT | Get | Length of the chain of hydraulic axes. |
UseDatFile | BOOL | Get, Set | A TRUE here signals that the axis loads its parameters with function blocks of the hydraulics library from a file during startup. A TRUE must be set before the first Cyclic call. |
Methods
Name | Description |
|---|---|
GetHydAxisRef() | Returns a |
[ | Used internally. |
[ | Used internally. |
Interfaces
Type | Description |
|---|---|
I_ExternalHydAxisLibRef | Standard interface to FB_ExternalHydAxisLibRef. |
Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT v3.1.4024.35 | PC or CX (x64, x86) | Tc3_PlasticFunctions v3.12.4.26 or higher Tc3_PlasticHydraulic v3.12.4.26 or higher |