FindTemplateWalsh

Match a template image with every location in the source image (using the Walsh transform) and evaluate the comparison results. Returns a sorted list of possible matches (best match first).
Can use available TwinCAT Job Tasks for executing parallel code regions.
Can return partial results when canceled by Watchdog.

Syntax

Definition:

HRESULT FindTemplateWalsh(
    HRESULT                hrPrev,
    ITcVnImage*            ipSrcImage,
    ITcVnImage*            ipTemplateImage,
    ITcVnContainer*&       ipMatches,
    float                  fMatchThreshold,
    ULONG                  nProjections,
    ULONG                  eOptions = FTWO_NONE,
    ULONG                  nRotations = 1,
    float                  fScaleFactor = 1,
    ETcVnInterpolationType eInterpolationType = IT_BILINEAR,
    ITcVnContainer**       pipMatchValues = nullptr
)

Parameters

Name

Type

Default

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcImage

ITcVnImage*

Source image (USINT or SINT, 1 or 3 channels)

ipTemplateImage

ITcVnImage*

Template image (same type as ipSrcImage, smaller width and height)

ipMatches

ITcVnContainer*&

Returns the matching positions (container type depends on eOptions; ContainerType_Vector_TcVnRotatedRectangle or ContainerType_Vector_TcVnVector4_REAL, where each element contains the center (x, y), the rotation angle in degrees, and the matching value of ipTemplateImage in ipSrcImage; container elements sorted by relevance (best match first))

fMatchThreshold

float

Threshold to separate relevant from irrelevant matches (0..1, 1.0 would be a perfect match.)

nProjections

ULONG

Number of Walsh projections to be used. The higher nProjections the more details are considered for matching. As the most relevant information is captured by the first Walsh projections, a small number (e.g., 5, 10, 25, or 50) is sufficient for many use cases. Each projection requires additional computation time. Therefore, it is advantageous to choose a low number of Walsh projections as long as the matching requirements are fulfilled. The allowed maximum of nProjections is determined by the width and the height of the template image.

eOptions

ULONG

FTWO_NONE

Flags controlling the matching process. (see ETcVnFindTemplateWalshOptions; default: TCVN_FTWO_NONE)

nRotations

ULONG

1

Number of rotations to be checked. (valid values: 1 (0°), 2 (0° and 180°), 4 (0°, 90°, 180°, and 270°), 8 (0°, 45°, ..., 315°), 16 (0°, 22.5°, ..., 337.5°), and 32 (0°, 11.25°, ..., 348.75°); default: 1)

fScaleFactor

float

1

Factor (0..1] to reduce source and template image width and height for better performance (but less accuracy!)

eInterpolationType

ETcVnInterpolationType

IT_BILINEAR

Image resize interpolation type (only used if fScaleFactor != 1, TCVN_IT_BILINEAR recommended for most cases)

pipMatchValues

ITcVnContainer**

nullptr

Optionally returns the matching values (ContainerType_Vector_REAL, same size and sort order as ipMatches. Set to 0 if not required.)

 Return value

HRESULT

Required License

TC3 Vision Matching