ExecuteNeuralNetwork (MO)

Execute a neural network using the provided image as input and provide the output of the specified output layers. The function doesn't perform any pre-processing or transformation.
Can use available TwinCAT Job Tasks for executing parallel code regions.

Syntax

Definition:

HRESULT ExecuteNeuralNetwork(
    HRESULT             hrPrev,
    ITcVnNeuralNetwork* ipNeuralNetwork,
    ITcVnImage*         ipSrcImage,
    ITcVnContainer*&    ipDestImages,
    ITcVnContainer*     ipOutputNames
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipNeuralNetwork

ITcVnNeuralNetwork*

Neural network model

ipSrcImage

ITcVnImage*

Source image (The image layout must be adapted to match the model's expected input format using e.g. F_VN_ConvertDataLayout or F_VN_ReshapeImage functions if necessary.)

ipDestImages

ITcVnContainer*&

Container of images containing the output from the specified layers.

ipOutputNames

ITcVnContainer*

Container of layer names whose outputs to be returned (ContainerType_Vector_String_SINT). If set to zero, the outputs of all unconnected output layers will be returned..

 Return value

HRESULT

Required License

TC3 Neural Network Realtime Inference

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision