Sigmoid

Apply the logistic function 1 / (1 + exp(-fSteepness * (x - fShift))) element-wise to a single- or multi-channel REAL image.

Syntax

Definition:

HRESULT Sigmoid(
    HRESULT      hrPrev,
    ITcVnImage*  ipSrcImage,
    ITcVnImage*& ipDestImage,
    float        fShift = 0.0f,
    float        fSteepness = 1.0f
)

Parameters

Name

Type

Default

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcImage

ITcVnImage*

Source image (REAL)

ipDestImage

ITcVnImage*&

Destination image (An appropriate destination image will be created if required.)

fShift

float

0.0f

Determines the intensity level around which the logistic function transitions.

fSteepness

float

1.0f

Controls the sharpness of the transition.

 Return value

HRESULT

Required License

TC3 Vision Base

System Requirements