F_VN_Sigmoid
Apply the standard logistic function 1 / (1 + exp(-x)) element-wise to a single- or multi-channel REAL image.
Syntax
Definition:
FUNCTION F_VN_Sigmoid : HRESULT
VAR_INPUT
ipSrcImage : ITcVnImage;
ipDestImage : Reference To ITcVnImage;
hrPrev : HRESULT;
END_VAR
Inputs
Name | Type | Description |
|---|---|---|
ipSrcImage | Source image (REAL) | |
ipDestImage | Reference To ITcVnImage | Destination image (An appropriate destination image will be created if required.) |
hrPrev | HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) |
Required License
TC3 Vision Base
System Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT V3.1.4024.59 or later | PC or CX (x64) with min. PL50, e.g. Intel 4-core Atom CPU | Tc3_Vision |
Return value