MorphologicalOperator

Apply a morphological operator.

Syntax

Definition:

HRESULT MorphologicalOperator(
    HRESULT                    hrPrev,
    ITcVnImage*                ipSrcImage,
    ITcVnImage*&               ipDestImage,
    ETcVnMorphologicalOperator eOperator,
    ITcVnImage*                ipStructuringElement
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcImage

ITcVnImage*

Source image (only 1 channel supported for reconstruction operators)

ipDestImage

ITcVnImage*&

Destination image (An appropriate destination image will be created if required.)

eOperator

ETcVnMorphologicalOperator

Operator type

ipStructuringElement

ITcVnImage*

Structuring element to be applied (Typically created via F_VN_CreateStructuringElement.)

MorphologicalOperator 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision