InverseFeatureTransform

Apply an inverse feature transform to one or more sample(s).

Syntax

Definition:

HRESULT InverseFeatureTransform(
    HRESULT       hrPrev,
    ITcVnMlModel* ipFeatureTransform,
    ITcUnknown*   ipSamples,
    ITcUnknown**  pipTransformed
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipFeatureTransform

ITcVnMlModel*

Feature transform instance to be used

ipSamples

ITcUnknown*

Container holding one or more of input sample(s) (ContainerType_Vector_REAL, ContainerType_Vector_LREAL, ContainerType_Vector_Vector_REAL, or ContainerType_Vector_Vector_LREAL)

pipTransformed

ITcUnknown**

Returns the transformed sample(s) using the same type like ipSamples

InverseFeatureTransform 1: Return value

HRESULT

Required License

TC3 Machine Learning Realtime Inference

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision