Histogram

Calculate the (multi-channel) histogram of an image.
Can use available TwinCAT Job Tasks for executing parallel code regions.

Syntax

Definition:

HRESULT Histogram(
    HRESULT          hrPrev,
    ITcVnImage*      ipSrcImage,
    ITcVnContainer*& ipDestHistogram,
    ULONG&           nBins = 0,
    double&          fLowerBound = 0,
    double&          fUpperBound = 0,
    ITcVnImage*      ipMask = nullptr
)

Parameters

Name

Type

Default

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcImage

ITcVnImage*

Source image

ipDestHistogram

ITcVnContainer*&

Returns a container with a multi-channel histogram, where every channel is represented as a vector of UDINT (ContainerType_Vector_Vector_UDINT. Non-zero interface pointers are reused.)

nBins

ULONG&

0

Desired number of bins or 0 to keep the default for the corresponding image format (in) and default number of bins (out)

fLowerBound

double&

0

Lower (inclusive) boundary of the 0-th histogram bin (in), or receive the default if fLowerBound AND fUpperBound are set to 0 (out)

fUpperBound

double&

0

Upper (exclusive) boundary of the last histogram bin nBins-1 (in), or receive the default if fLowerBound AND fUpperBound are set to 0 (out)

ipMask

ITcVnImage*

nullptr

Source image mask (TCVN_ET_USINT, 1 channel. Mask is optional, set to 0 if not required.)

Histogram 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision