EnclosingRectangle

Searches for a minimum area rectangle enclosing a set of points.

Syntax

Definition:

HRESULT EnclosingRectangle(
    HRESULT               hrPrev,
    ITcVnContainer*       ipPointSet,
    TcVnRotatedRectangle& stRectangle
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipPointSet

ITcVnContainer*

Source point set (ContainerType_Vector_TcVnPoint2_DINT or ContainerType_Vector_TcVnPoint2_REAL; The elements of this container are the individual points.)

stRectangle

TcVnRotatedRectangle&

Returns the determined rectangle

EnclosingRectangle 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision