DetectBlobs
Detects blob-contours. Applies a threshold, a contour search and offers several options for filtering the found contours. Provides easy setup for multiple thresholds and combination of results.
Can use available TwinCAT Job Tasks for executing parallel code regions.
Can return partial results when canceled by Watchdog.
Syntax
Definition:
HRESULT DetectBlobs(
HRESULT hrPrev,
ITcVnImage* ipSrcImage,
ITcVnContainer*& ipBlobContours,
TcVnParamsBlobDetection& stParams,
TcVnPoint& aOffset = {0, 0}
)Parameters
|
Name |
Type |
Default |
Description |
|---|---|---|---|
|
hrPrev |
|
HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) | |
|
ipSrcImage |
|
Source image (USINT or REAL, 1 channel or 3 channel (3 channel input is expected to be RGB and internally converted to Gray)) | |
|
ipBlobContours |
|
Returns a container which is filled with the found contours (ContainerType_Vector_Vector_TcVnPoint2_DINT; The elements of this container are single contours. Non-zero interface pointers are reused.) | |
|
stParams |
|
Parameters to filter the detected contours. | |
|
aOffset |
{0, 0} |
Offset by which every contour point is shifted |
Required License
TC3 Vision Base
Return value