CreateStructuringElement

Creates a structuring element for the usage with morphological operators and allocate an appropriate data buffer. The initial reference count is set to one if a new image interface is created and kept, otherwise.

Syntax

Definition:

HRESULT CreateStructuringElement(
    HRESULT                      hrPrev,
    ITcVnImage*&                 ipStructuringElement,
    ETcVnStructuringElementShape eShape,
    ULONG                        nWidth,
    ULONG                        nHeight
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipStructuringElement

ITcVnImage*&

Returns the created structuring element (Non-zero interface pointers are reused.)

eShape

ETcVnStructuringElementShape

Shape of the structuring element (rectangle, cross, or ellipse)

nWidth

ULONG

Width

nHeight

ULONG

Height

CreateStructuringElement 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision