CreatePcaTransformViaComponentNum

Create a PCA-based feature transform from the provided data where the number of prinicpal components to be used is predefined. The maximum number of principal components that can be computed equals the minimum of the number of samples and the number of features. The initial reference count is set to one if a new model is created and kept, otherwise.

Syntax

Definition:

HRESULT CreatePcaTransformViaComponentNum(
    HRESULT        hrPrev,
    ITcVnMlModel*& ipMlModel,
    ITcUnknown*    ipSamples,
    ULONG          nComponentNum
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipMlModel

ITcVnMlModel*&

Returns the created feature transform (Non-zero interface pointers are reused.)

ipSamples

ITcUnknown*

Container holding a batch of input samples (ContainerType_Vector_Vector_REAL or ContainerType_Vector_Vector_LREAL)

nComponentNum

ULONG

Number of principal components (A value of 0 results in the automatic computation of the maximum number of components.)

CreatePcaTransformViaComponentNum 1: Return value

HRESULT

Required License

TC3 Machine Learning Realtime Inference

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision