ContainerAverageVarianceElementwise (3)

Calculate the elementwise average and variance of 3D elements in a container.

Syntax

Definition:

HRESULT ContainerAverageVarianceElementwise(
    HRESULT            hrPrev,
    ITcVnContainer*    ipSrcContainer,
    TcVnVector3_LREAL& aAverage,
    TcVnVector3_LREAL& aVariance
)

Parameters

Name

Type

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcContainer

ITcVnContainer*

Source container with 3D points or vectors

aAverage

TcVnVector3_LREAL&

Returns the calculated average values

aVariance

TcVnVector3_LREAL&

Returns the calculated variance values

ContainerAverageVarianceElementwise (3) 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision