CannyEdgeDetection

Find edges using the Canny edge detection algorithm.
Can use available TwinCAT Job Tasks for executing parallel code regions.

Syntax

Definition:

HRESULT CannyEdgeDetection(
    HRESULT      hrPrev,
    ITcVnImage*  ipSrcImage,
    ITcVnImage*& ipDestImage,
    double       fThresholdLow,
    double       fThresholdHigh,
    ULONG        nApertureSize = 3,
    bool         bL2Gradient = false
)

Parameters

Name

Type

Default

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

ipSrcImage

ITcVnImage*

Source image (elements of type USINT)

ipDestImage

ITcVnImage*&

Destination image (elements of type USINT. An appropriate destination image will be created if required.)

fThresholdLow

double

Low threshold

fThresholdHigh

double

High threshold

nApertureSize

ULONG

3

Aperture size for the Sobel operator (3, 5, 7)

bL2Gradient

bool

false

If true, the more accurate (and slower) L2 norm is used instead of the L1 norm

CannyEdgeDetection 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU

Tc3_Vision