ApproximatePolygon
Approximate a contour to a simplified polygon (using the Douglas-Peucker algorithm).
Syntax
Definition:
HRESULT ApproximatePolygon(
HRESULT hrPrev,
ITcVnContainer* ipSrcContour,
ITcVnContainer*& ipDestContour,
double fMaxDist,
bool bClosed
)Parameters
|
Name |
Type |
Description |
|---|---|---|
|
hrPrev |
HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) | |
|
ipSrcContour |
Single contour (ContainerType_Vector_TcVnPoint2_DINT or ContainerType_Vector_TcVnPoint2_REAL; The elements of this container are the points of the contour.) | |
|
ipDestContour |
Returns a container which is filled with the approximated polygon points (same type ID as ipSrcContour; Non-zero interface pointers are reused.) | |
|
fMaxDist |
double |
Maximum distance between the original contour and its approximation |
|
bClosed |
bool |
Specify, if the contour is closed (first and last points connected) or not |
Required License
TC3 Vision Base
System Requirements
Development environment | Target platform | PLC libraries to include |
|---|---|---|
TwinCAT V3.1.4024.59 or later | PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU | Tc3_Vision |
Return value