ApplyTranslationToAffineTransformation

Apply a translation to an existing 2D affine transformation matrix.

Syntax

Definition:

HRESULT ApplyTranslationToAffineTransformation(
    HRESULT              hrPrev,
    TcVnMatrix2x3_LREAL& aTransformationMatrix,
    double               fDeltaX,
    double               fDeltaY,
    bool                 bUsePreMultiplication = true
)

Parameters

Name

Type

Default

Description

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

aTransformationMatrix

TcVnMatrix2x3_LREAL&

Affine transformation matrix to which the translation is applied

fDeltaX

double

Translation in x direction

fDeltaY

double

Translation in y direction

bUsePreMultiplication

bool

true

Select if pre- or post-multiplication should be used

ApplyTranslationToAffineTransformation 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel Atom® 4-core CPU