F_VN_StartAbsWatchdogExp
Start a cooperative watchdog given an absolute stop time. (expert function)
Syntax
Definition:
FUNCTION F_VN_StartAbsWatchdogExp : HRESULT
VAR_INPUT
tStop : DINT;
eWatchdogAccType : ETcWatchdogAccumulationType;
hrPrev : HRESULT;
END_VAR
Inputs
|
Name |
Type |
Description |
|---|---|---|
|
tStop |
DINT |
Stop time in us |
|
eWatchdogAccType |
Accumalation method used for combining the results of multiple functions enclosed by this watchdog | |
|
hrPrev |
HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) |
Required License
TC3 Vision Base
System Requirements
|
Development environment |
Target platform |
PLC libraries to include |
|---|---|---|
|
TwinCAT V3.1.4024.59 or later |
PC or CX (x64) with min. PL50, e.g. Intel 4-core Atom CPU |
Tc3_Vision |
Return value