F_VN_ReserveContainerMemory
Reserve container memory (call with maximum required number of elements before manually appending elements for better performance)
Syntax
Definition:
FUNCTION F_VN_ReserveContainerMemory : HRESULT
VAR_INPUT
ipContainer : ITcVnContainer;
nElements : ULINT;
hrPrev : HRESULT;
END_VAR
Inputs
|
Name |
Type |
Description |
|---|---|---|
|
ipContainer |
Container for which to reserve the memory | |
|
nElements |
ULINT |
Number of elements for which the container should reserve memory |
|
hrPrev |
HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) |
Required License
TC3 Vision Base
System Requirements
|
Development environment |
Target platform |
PLC libraries to include |
|---|---|---|
|
TwinCAT V3.1.4024.59 or later |
PC or CX (x64) with min. PL50, e.g. Intel 4-core Atom CPU |
Tc3_Vision |
Return value