F_VN_GetConnectedComponent
Get the mask image of a connected component from a label image based on the label ID.
Syntax
Definition:
FUNCTION F_VN_GetConnectedComponent : HRESULT
VAR_INPUT
ipLabelImage : ITcVnImage;
nLabelID : DINT;
ipMaskImage : Reference To ITcVnImage;
hrPrev : HRESULT;
END_VAR
Inputs
|
Name |
Type |
Description |
|---|---|---|
|
ipLabelImage |
Image containing labels for each pixel (1 channel DINT or UINT). | |
|
nLabelID |
DINT |
Value of the requested label |
|
ipMaskImage |
Reference To ITcVnImage |
Returns a mask image marking the pixels that belong to the component (1 channel USINT.) |
|
hrPrev |
HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.) |
Required License
TC3 Vision Base
System Requirements
|
Development environment |
Target platform |
PLC libraries to include |
|---|---|---|
|
TwinCAT V3.1.4024.59 or later |
PC or CX (x64) with min. PL50, e.g. Intel 4-core Atom CPU |
Tc3_Vision |
Return value