F_VN_ConvexHullPoints

F_VN_ConvexHullPoints 1:

Determines the convex hull of a point set.

Syntax

Definition:

FUNCTION F_VN_ConvexHullPoints : HRESULT
VAR_INPUT
    ipPointSet   : ITcVnContainer;
    ipConvexHull : Reference To ITcVnContainer;
    hrPrev       : HRESULT;
END_VAR

F_VN_ConvexHullPoints 2: Inputs

Name

Type

Description

ipPointSet

ITcVnContainer

Source point set (ContainerType_Vector_TcVnPoint2_DINT or ContainerType_Vector_TcVnPoint2_REAL; The elements of this container are the individual points.)

ipConvexHull

Reference To ITcVnContainer

Returns a container which is filled with the sorted convex hull points (same type ID as ipPointSet; Non-zero interface pointers are reused.)

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

F_VN_ConvexHullPoints 3: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1.4024.59 or later

PC or CX (x64) with min. PL50, e.g. Intel 4-core Atom CPU

Tc3_Vision