F_VN_ClaheExp

F_VN_ClaheExp 1:

Apply Constrast Limited Adaptive Histogram Equalization. This applies local histogram equalization to individual tiles. (expert function)
Can use available TwinCAT Job Tasks for executing parallel code regions.

Syntax

Definition:

FUNCTION F_VN_ClaheExp : HRESULT
VAR_INPUT
    ipSrcImage  : ITcVnImage;
    ipDestImage : Reference To ITcVnImage;
    fClipLimit  : LREAL;
    nTilesX     : UDINT;
    nTilesY     : UDINT;
    hrPrev      : HRESULT;
END_VAR

F_VN_ClaheExp 2: Inputs

Name

Type

Description

ipSrcImage

ITcVnImage

Source image (TCVN_ET_USINT or TCVN_ET_UINT, 1 channel)

ipDestImage

Reference To ITcVnImage

Returns the resulting image (An appropriate image will be created if required.)

fClipLimit

LREAL

Threshold for contrast limit (set to <= 0 to disable clipping)

nTilesX

UDINT

Number of tiles in x direction

nTilesY

UDINT

Number of tiles in y direction

hrPrev

HRESULT

HRESULT indicating the result of previous operations (If SUCCEEDED(hrPrev) equals false, no operation is executed.)

F_VN_ClaheExp 3: Return value

HRESULT

Required License

TC3 Vision Base