MC_ReadHalt
This function block provides a read-only view on the parameters and status of the halt command attached to CommandHandle. While Enable is TRUE the outputs are updated on every call. Valid signals that they describe a halt command. The Command* outputs stay FALSE until the axis has processed the command.
Syntax
Definition:
FUNCTION_BLOCK MC_ReadHalt
VAR_IN_OUT
CommandHandle : Reference To MC_CommandHandle;
END_VAR
VAR_INPUT
Enable : BOOL;
END_VAR
VAR_OUTPUT
Valid : BOOL;
Error : BOOL;
ErrorId : UDINT;
Deceleration : LREAL;
Jerk : LREAL;
CommandQueued : BOOL;
CommandDone : BOOL;
CommandActive : BOOL;
CommandAborted : BOOL;
CommandError : BOOL;
CommandErrorId : UDINT;
END_VAR
Inputs
|
Name |
Type |
Description |
|---|---|---|
|
Enable |
BOOL |
The outputs are updated while TRUE. |
In/Outputs
|
Name |
Type |
Description |
|---|---|---|
|
CommandHandle |
Reference To MC_CommandHandle |
Handle of the command to observe |
Outputs
|
Name |
Type |
Description |
|---|---|---|
|
Valid |
BOOL |
The outputs describe the halt command attached to CommandHandle. |
|
Error |
BOOL |
Error occurred within function block, e.g. no command attached to CommandHandle or not a halt command. |
|
ErrorId |
UDINT |
Error identifier |
|
Deceleration |
LREAL |
Maximum deceleration ([PosUnit]/s^2, positive) |
|
Jerk |
LREAL |
Maximum jerk ([PosUnit]/s^3, positive) |
|
CommandQueued |
BOOL |
Command is queued for execution. |
|
CommandDone |
BOOL |
Zero dynamics reached, axis transferred to state Standstill. |
|
CommandActive |
BOOL |
The command is currently active. |
|
CommandAborted |
BOOL |
Command is aborted by another command. |
|
CommandError |
BOOL |
Error occurred while executing the command. |
|
CommandErrorId |
UDINT |
Error identifier of the command |
Possible error codes
For this function block, the following values, among others, are possible for the ErrorId output:
Error(Hex) | Error(Dec) | Error type | Description |
|---|---|---|---|
0x8189 | 33161 | Function Block | Invalid reference passed to function block. An invalid reference (or pointer) was used in a function block call. This can happen if a reference type is used before it was initialized. |
0x81ba | 33210 | Function Block | Invalid command type passed to function block. The command type passed to the function block does not match the command expected by it (e.g., a Read function block is given a command of a different type than the one it reads). |
0x81c9 | 33225 | Function Block | Command handle is not initialized. The MC_CommandHandle object does not contain an attached command. |
An overview of all NC error codes can be found here:
If the data size is invalid, the error ADSERR_DEVICE_INVALIDSIZE (0x705; 1797) may occur.
You can find an overview of all ADS return codes here:
Version information
- TwinCAT Standard >= v3.1.4026.23.1
- TF5500 MC3 Base >= v4.0.24