CamActivationReadOptions

Activation options of a cam command as given to it, reported by the MC_ReadCam* function blocks.

Syntax

Definition:

TYPE CamActivationReadOptions :
STRUCT
    Mode               : ECamActivationMode;
    Position           : LREAL;
    ReferenceObjectOid : OTCID;
END_STRUCT
END_TYPE

Parameters

Name

Type

Default

Description

Mode

ECamActivationMode

Instantaneous

Activation mode defining when the cam operation takes effect.

Position

LREAL

#Ignore

Activation position on the master of the reference cam object: a master cam position for AtMasterCamPosition, or a master axis position for AtMasterAbsolutePosition. Not used by Instantaneous and AtBoundary.

ReferenceObjectOid

OTCID

 

Object ID of the cam object given as ActivationOptions.ReferenceObject, 0 if none was given.

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5550 MC3 Camming >= v4.0.24 (includes TF5500 MC3 Base >= v4.0.24)