CamCharacteristics

Computed characteristics of a cam table describing its motion profile properties.

Syntax

Definition:

TYPE CamCharacteristics :
STRUCT
    NominalMasterVelocity       : LREAL;
    StartPoint                  : CamProfilePoint;
    EndPoint                    : CamProfilePoint;
    PointAtMinSlavePosition     : CamProfilePoint;
    PointAtMinSlaveVelocity     : CamProfilePoint;
    PointAtMinSlaveAcceleration : CamProfilePoint;
    PointAtMinSlaveJerk         : CamProfilePoint;
    PointAtMaxSlavePosition     : CamProfilePoint;
    PointAtMaxSlaveVelocity     : CamProfilePoint;
    PointAtMaxSlaveAcceleration : CamProfilePoint;
    PointAtMaxSlaveJerk         : CamProfilePoint;
    SlaveMeanAbsoluteVelocity   : LREAL;
    SlaveEffectiveAcceleration  : LREAL;
    Oid                         : OTCID;
    NumberOfPoints              : UDINT;
    NumberOfActivePoints        : UDINT;
    NumberOfActiveSegments      : UDINT;
    IsValid                     : BOOL;
    IsPeriodic                  : BOOL;
    MinContinuityRequirement    : EContinuity;
END_STRUCT
END_TYPE

Parameters

Name

Type

Default

Description

NominalMasterVelocity

LREAL

0.0

Constant master velocity at which the slave velocity, acceleration and jerk are evaluated over time.

StartPoint

CamProfilePoint

 

Cam profile point at the start of the table.

EndPoint

CamProfilePoint

 

Cam profile point at the end of the table.

PointAtMinSlavePosition

CamProfilePoint

 

Cam profile point where the slave position reaches its minimum.

PointAtMinSlaveVelocity

CamProfilePoint

 

Cam profile point where the slave velocity reaches its minimum.

PointAtMinSlaveAcceleration

CamProfilePoint

 

Cam profile point where the slave acceleration reaches its minimum.

PointAtMinSlaveJerk

CamProfilePoint

 

Cam profile point where the slave jerk reaches its minimum.

PointAtMaxSlavePosition

CamProfilePoint

 

Cam profile point where the slave position reaches its maximum.

PointAtMaxSlaveVelocity

CamProfilePoint

 

Cam profile point where the slave velocity reaches its maximum.

PointAtMaxSlaveAcceleration

CamProfilePoint

 

Cam profile point where the slave acceleration reaches its maximum.

PointAtMaxSlaveJerk

CamProfilePoint

 

Cam profile point where the slave jerk reaches its maximum.

SlaveMeanAbsoluteVelocity

LREAL

0.0

Mean absolute velocity of the slave over the entire cam table range.

SlaveEffectiveAcceleration

LREAL

0.0

RMS (effective) acceleration of the slave over the entire cam table range.

Oid

OTCID

0

Object ID of the cam table these characteristics belong to.

NumberOfPoints

UDINT

0

Total number of profile points in the cam table.

NumberOfActivePoints

UDINT

0

Number of non-ignored profile points in the cam table.

NumberOfActiveSegments

UDINT

0

Number of active interpolation segments between the profile points.

IsValid

BOOL

false

TRUE if the characteristics have been computed successfully.

IsPeriodic

BOOL

false

TRUE if the cam table is periodic (start and end boundary conditions match).

MinContinuityRequirement

EContinuity

PositionVelocityAcceleration

Minimum continuity level required for smooth operation of the cam table.

Further information

This structure contains the most important properties of a cam plate and can be retrieved using the MC_CamObject.ReadCharacteristics() method.

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5550 MC3 Camming >= v4.0.6 (includes TF5500 MC3 Base >= v4.0.6)