CamActivationOptions

Defines when a cam command takes effect and which coupled cam object that is measured against.

Syntax

Definition:

TYPE CamActivationOptions :
STRUCT
    Mode            : ECamActivationMode;
    Position        : LREAL;
    ReferenceObject : Type_CouplingFunction1D;
END_STRUCT
END_TYPE

Parameters

Name

Type

Default

Description

Mode

ECamActivationMode

Instantaneous

Activation mode defining when the cam operation takes effect.

Position

LREAL

#Ignore

Activation position on the master of the ReferenceObject: a master cam position within the master range of its cam object for AtMasterCamPosition, or a master axis position for AtMasterAbsolutePosition. Ignored for Instantaneous and AtBoundary.

ReferenceObject

Type_CouplingFunction1D

 

Coupled cam object whose master the activation is measured against; it may be the cam object the command adds. Ignored for Instantaneous. If not set, CamRemove and CamExchange use the cam object they remove, CamScaling uses its own cam object, and CamIn and CamAdd use the only cam object coupled to the slave, or the one they add if none is coupled yet. Must be set where this is ambiguous, e.g. with several coupled cam objects.

Further information

This structure contains the most important properties of a cam plate and can be retrieved using the MC_CamObject.ReadCharacteristics() method.

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5550 MC3 Camming >= v4.0.6 (includes TF5500 MC3 Base >= v4.0.6)