Round tube, lateral surface (kinematic ID 15)

Parameters are defined under the ID 15 of the kinematic offsets (P-CHAN-00263 and P-CHAN-00094).

If required, PCS modulo calculation can be enabled by the parameter HD10.

HD offset

param[i]

Description

Unit

HD1

0

Z offset tool fixing point - Tool carrier reference point

1.0 E-4 mm

HD2

1

Angle offset of rotary axis

1.0 E-4°

HD3

2

X offset tool fixing point - Tool carrier reference point

1.0 E-4 mm

HD4

3

-

 

HD5

4

Z offset of rotary axis U to machine zero point

1.0 E-4 mm

HD6

5

X offset of rotary axis U to machine zero point

1.0 E-4 mm

HD10

9

PCS modulo calculation
0: inactive
1: active

[ - ]

The general description is contained in the channel parameter list under P-CHAN-00263 and P-CHAN-00094.

Round tube, lateral surface (kinematic ID 15) 1:
Kinematic offsets for lateral surface machining