Programming

The use of online tool radius compensation (online TRC) is defined in the programming of the INVERSE and ONLINE options. The selected setting becomes effective when tool radius compensation (TRC) is activated by G41 or G42. Online TRC is deselected when TRC is deactivated with G40.

Notice

In order to use online TRC, both options

#TRC [INVERSE=1 ONLINE=1] must be set.

Otherwise an error message with ID 22125 is output.

Programming Example

Selecting TRC with options set

N10 V.G.WZ_AKT.R = 0.3
N20 G26
N30 G138
; …
N70 #TRC [INVERSE=1 ONLINE=1] ( Set options)
N100 G0 X0 Y0 U0 V0
N280 G41     ( Select TRC)
( of the contour)
; …
N500 G40     ( Deselect TRC)
; ...
N550 M30

Programming the tool radius

Identical tool radii in both paths

N.. V.G.WZR=0.15

Alternatively:

N.. V.G.WZR=0.15 : X100 Y20: U100 V20

Different tool radii in both paths

N.. : V.G.WZR=0,139 : V.G.WZR=0.15
Alternatively:
N.. : V.G.WZR=0.139 X100 Y20 : V.G.WZR=0.15 U100 V20

Define the tool radius in the reference path

N.. : V.G.WZR=0,134 :

Define the tool radius in the second path

N.. : : V.G.WZR=0,151