Activating the Vibration Guard
The Vibration Guard can be parameterised and/or activated in 2 ways:
- Permanently and for a specific axis in the axis lists.
- For a specific program and at the same time for all axes in the #VIB GUARD command in the NC program.
No preconfiguration is required in the axes in order to configure and activate the Vibration Guard.
If the axes in an axis group are configured with different settings, this will lead to asynchronous axis behaviour. It is therefore recommended to always configure the same settings within an axis group. |
However, a mixed form is possible: For example, settings can be preconfigured for specific axes in the axis lists and the Vibration Guard can then be flexibly activated or deactivated by the NC command in the NC program.
Configuration or activation in the NC program has priority over configuration or activation in the axis lists.
The Vibration Guards can also be globally and flexibly activated/deactivated or reparameterised in the NC program for all axes during machining work (between motion blocks) (see Programming example).