Measure angle between 2 drilled holes (C axis)

The centre point of the drilled holes is calculated by 4 measured points (see SysMeasWcs8) and by the angle between the drilled holes in relation to the X axis.

The touch probe must be positioned as centrally as possible above the first drilled hole either manually or in automatic mode.

If no C axis is configured, call the cycle without transferring @P7. The twist in C can be manually transferred to the related zero offset by evaluating the output variables in the post-program.

The reference angle (@P12) described the desired angle or the angle to be achieved. The reference angle (@P12) is added to the calculated C value to determine the output angle (V.CYC.SysRetC): Calculated C value - @P12 = output value (V.CYC.SysRetC). Example 1: Calculated C value = 45 degrees, @P12 = 45 degrees, output angle (V.CYC.SysRetC) = 0 Example 2: Calculated C value = 45 degrees, @P12 = 0 degrees (V.CYC.SysRetC= 45

The coordinate system can be adapted accordingly by using the #CS command (see programming example.

To obtain correct measurement results, the requirements for measuring must be adhered to.

Measure angle between 2 drilled holes (C axis) 1:
Measure angle between 2 drilled holes (C axis)