Activating workspace and protection areas
Commands for selection
The tool TCP is checked for violations with all activated workspace and protection areas. Control areas can either be activated individually via their unique ID or they can all be activated at once.
When workspaces are activated, the TCP must already be located in the valid workspace. In the same way, when a protection area is activated, the TCP may not incur any violation at the current position.
The NC command to select a control area contains the following syntax elements:
Syntax of Selecting a control area |
#CONTROL AREA ON [ALL] | [ ID=.. ] |
ID=.. | Identification number of the control area (ID). |
ALL | Activate all defined control areas. |
Programming Example
Activating workspace and protection areas
#CONTROL AREA ON [ID3] (Activate specific control area)
#CONTROL AREA ON ALL (Activate all defined control areas)