Define spindle name #SPINDLE NAME

Function available as of V3.1.3140.0.

A new name for the spindle can be entered by using the NC command #SPINDLE NAME.

Syntax :

#SPINDLE NAME [ AXNEW=.. [AX=.. | AXNR=..] ]

 

AXNEW=..

New spindle identifier starting with “S”

AX

Previous spindle identifier.

AXNR

Logical axis number P-AXIS-00016 of the spindle that is to receive the new identifier.

Conditions:

Programming Example

Renaming spindle identifiers

; The channel parameters contain the following entries:
; S1 with axis number 11 and S2 with axis number 17
#SPINDLE NAME [AXNEW=S11, AXNR=11] ; S1 -> S11
#SPINDLE NAME [AXNEW=S111, AX=S11] ; S11 -> S111
#SPINDLE NAME [AXNEW=S22, AX=S2]   ; S2 -> S22
#MAIN SPINDLE [S22]                ; S22 becomes main spindle

Reset spindle name

The NC command #SPINDLE NAME DEFAULT can be used to reset a spindle identifier to the default value specified in the channel parameter list.

If no axis is specified in the NC command, all spindle identifiers in the channel are reset to the values in the channel parameter list.

Syntax :

#SPINDLE NAME DEFAULT [AX=.. | AXNR=..]

 

AX

Current spindle identifier.

AXNR

Logical axis number P-AXIS-00016 of the spindle that is to be reset.

Conditions:

Programming Example

Reset spindle identifiers

; The channel parameters contain the following entries:
; S1 with axis number 11 and S2 with axis number 17
; Initial situation: Axis 11 with identifier S111
;               Axis 17 with identifier S22
#SPINDLE NAME DEFAULT [AX=S111] ; S111 -> S1
#SPINDLE NAME DEFAULT           ; S22  -> S2