Parameter

P-STUP-00206

Logical ID of a client channel in a Job Manager group

Description

The parameter defines the logical ID of a client channel. This logical ID can be requested in the agent channel by V.G.IP_NR. Due to the necessary uniqueness, no second agent channel may use the same logical ID in the same Job Manager group.

Parameter

jobmanager.group[i].master[j].log_id
where i = 0, 1 (index of the Job Manager group, max. 1)
where j = 0 … n (index of a continuous list element. n: application-specific)

Data type

UNS16

Data range

1 … 65536

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110

IMPORTANT: If the agent is not commanded by a client, the call of "V.G.IP_NR" returns the "log_id" of the agent.

P-STUP-00207

Logical ID of a client channel in a Job Manager group

Description

The client channel (master) designated by this parameter in a Job Manager group corresponds to an existing CNC channel. It cannot be assigned to any other group, neither as an agent (slave) nor as a client (master) The number used must correspond to an existing channel number.

Parameter

jobmanager.group[i].master[j].channel_id (application-specific)

where i = 0, 1 (index of Job Manager group, max. 1)
where j = 0..n (index of a continuous list element. n: application-specific)

Data type

UNS16

Data range

1 to 12 (application-specific)

Dimension

----

Default value

0 *

Remarks

Available as of V3.1.3110

* The value corresponds to the statement: Parameter is not used. If all jobmanager. group[i].master[j].channel_id parameters in a Job Manager group are "0", the Job Manager is deactivated for the group.

The client channel corresponds to a “normal” channel. The Job Manager configuration extends the command set to include Job Manager commands (see [FCT-M10]). This also includes commanding all agents (slaves) in the same Job Manager group with jobs.

P-STUP-00208

Logical ID of an agent channel in a Job Manager group

Description

The parameter defines the logical ID of an agent channel. Every agent (slave) in a Job Manager group is invoked by commands from the client by its logical ID "log_id” at the start. Due to the necessary uniqueness, no second agent channel may use the same logical ID in the same Job Manager group.

Parameter

Jobmanager.group[i].cnc_slave[j].log_idwhere
where i = 0, 1 (index of Job Manager group, max. 1)
where j = 0..n (index of a continuous list element. n: application-specific)

Data type

UNS16

Data range

1 … 65536

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110

There are two types of agent: CNC channels and PLC units.

The logical ID always refers to a particular type

P-STUP-00209

Agent channel in a Job Manager group

Description

The agent channel (slave) designated by this parameter in a Job Manager group corresponds to an existing CNC channel. It cannot be assigned to any other group, neither as an agent (slave) nor as client (master).
The number used must correspond to an existing channel number.

Parameter

jobmanager.group[i]. cnc_slave[j].channel_id (application-specific)
where i = 0, 1 (index of Job Manager group, max. 1)
where j = 0..n (index of a continuous list element. n: application-specific)

Data type

UNS16

Data range

1 … (application-specific)

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110

The agent channel behaves like a "normal" channel. It has the additional property of being requested by any master in the same Job Manager group to execute a job. Job completion is signalled back to the client in the controller.

P-STUP-00210

Logical ID of agent PLC unit in a Job Manager group

Description

The parameter defines the logical ID of an agent PLC unit. Every PLC agent (slave) in a Job Manager group is invoked by commands from the client by its logical ID "log_id”. Due to the necessary uniqueness, no second agent PLC unit may use the same logical ID in the same Job Manager group.

Parameter

jobmanager.group[i]. Plc_slave[j].log_id
where i = 0, 1 (index of the Job Manager group, max. 1)
where j = 0…n (index of a continuous HLI list element. n: application-specific)

Data type

UNS16

Data range

1 … 65536

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110

P-STUP-00211

Agent PLC unit in a Job Manager group

Description

The agent PLC unit (slave) in a Job Manager group designated by this parameter corresponds to an interface on the HLI. After assignment it cannot be assigned to any other group.

Parameter

jobmanager.group[i].hli_index (application-specific)
where i = 0, 1 (index of the Job Manager group, max. 1)
where j = 0..n (index of a continuous HLI list element
n: application-specific)

Data type

UNS08

Data range

0 to 31 (application-specific)

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110

An agent PLC unit has the property of being requested by any master in the same Job Manager group to execute a job. Job completion is signalled back to the client in the controller.

P-STUP-00212

Parameter list of an agent PLC unit in a Job Manager group

Description

The agent PLC unit (slave) in a Job Manager group can receive parameters from the client at the start. The data structure described a declared parameter list in "jobmanager.coding[i].list" (P-STUP-00204).
The parameter required here corresponds to the index [i] in "jobmanager.coding[i].list".

Parameter

jobmanager.group[i].plc_slave[j].coding
where i = 0, 1 (index of Job Manager group, max. 1)
where j = 0..n (index of consecutive HLI list element
n: application-specific)

Data type

UNS08

Data range

0 to 2 (application-specific)

Dimension

----

Default value

0

Remarks

Available as of V3.1.3110