Evaluation of SERCOS state bit drive follows command (P-AXIS-00411)
P-AXIS-00411 | Evaluation of SERCOS state bit drive follows command (SERCOS) | |
Description | Many SERCOS drives supply the information “drive follows setpoints” in bit 3 of their status word (bit mask 0x0008). Parameter P-AXIS-00411 achieves that this bit is taken into account for the calculation of the HLI state signal StateLR_Data.X_ReadyPowerOn (see [HLI]). If this parameter is set, the HLI signal ReadyForPowerOn is set only when bits (0x4000 and 0x0008) are set in the SERCOS state word. In the following cases the HLI state signal StateLR_Data.X_ReadyPowerOn is derived only from SERCOS state bit 0x4000 regardless of the setting of P-AXIS-00411:
SERCOS state bit 0x8000 (Ready for power on) is not set. | |
Parameter | antr.sercos.evaluate_drive_follows_cmd | |
Data type | BOOLEAN | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | SERCOS | |
Remarks | It is only useful to apply this parameter if the drive provides state bit 0x0008. This information has to be taken from the drive documentation. | |