Evaluating status bit “Drive follows command values” (P-AXIS-00830)
P-AXIS-00830 | Evaluating status bit “Drive follows command values” | |
Description | Many SERCOS drives supply the information “Drive follows command values” in a bit of their status word. This parameter controls the inclusion of this bit to calculate the HLI status signal lr_state.ready_for_power_on_r. The HLI signal lr_state.ready_for_power_on_r is only set if:
The bit is not evaluated in the following cases:
| |
Parameter | antr.evaluate_drive_follows_cmd | |
Data type | SGN08 | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | -1 | |
Drive types | CANopen, SERCOS | |
Remarks | Parameter available as of V3.1.3081.7 This parameter replaces the parameter P-AXIS-00411 for the SERCOS drive type.. It is only useful to use this parameter if the drive controller supplies the corresponding status bit. This information has to be taken from the drive documentation. | |