Consideration of other axis compensations (P-COMP-00057)

P-COMP-00057

Consideration of other axis compensations

Description

By default, leadscrew error compensation also considers the compensation values generated from other axis compensations, e.g. cross and plane compensation. With direction-dependent spindle leadscrew error compensation (see P-COMP-00021) this may result in the undesirable occurrence of backlash under certain circumstances.

The parameter set_pos_without_comp can disable the inclusion of other compensation values in the calculation.

Parameter

kw.ssfk.set_pos_without_comp

Data type

BOOLEAN

Data range

0: Compensation values of other compensations are considered in the leadscrew error compensation.

1: Compensation values of other compensations are not considered.

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks