Consideration of other axis compensations (P-COMP-00057)
| P-COMP-00057 | Consideration of other axis compensations | |
| Description | By default, leadscrew error compensation also considers the compensation values generated from other axis compensations, e.g. cross and plane compensation. With direction-dependent spindle leadscrew error compensation (see P-COMP-00021) this may result in the undesirable occurrence of backlash under certain circumstances. The parameter set_pos_without_comp can disable the inclusion of other compensation values in the calculation. | |
| Parameter | kw.ssfk.set_pos_without_comp | |
| Data type | BOOLEAN | |
| Data range | 0: Compensation values of other compensations are considered in the leadscrew error compensation. 1: Compensation values of other compensations are not considered. | |
| Axis types | T, R, S | |
| Dimension | T: ---- | R,S: ---- | 
| Default value | 0 | |
| Remarks | 
 | |