Description

P-AXIS-00174

Activation of plane compensation

Description

This parameter activates the plane compensation (2-dimensional cross compensation).

Parameter

lr_param.crosscomp2

Data type

BOOLEAN

Data range

0/1

Axis types

T

Dimension

T: ----

 

Default value

0

Drive types

----

Remarks

 

P-COMP-00061

Maximum number of table entries for plane compensation

Description

This plane compensation parameter (FCT-C5) saves the memory space required for a particular number of table entries.

 

The size of the actually used compensation table is defined by `last_index:master1` (P-COMP-00010) and `last_index_master2` (P-COMP-00011)

and the following must apply:

 

(`last_index_master1` + 1) * (`last_index_master2` + 1) <= `max_points`

 

If  `max_points` is not specified (or assigned the value 0), the previous restrictions

apply to `last_index_master1` and `last_index_master2`.

  • 0 <= `last_index_master1` <= 100
  • 0 <= `last_index_master2` <= 100

Parameter

kw.crosscomp2.max_points

Data type

UNS32

Data range

0 <= P-COMP-00061

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

10201 (*)

Remarks

The parameter value can no longer be changed after start-up or after lists are reloaded. Otherwise error ID 110640 is output.

 

If P-COMP-00061 is not specified (or assigned the value 0), the default value is assigned to P-COMP-00061 for downward compatibility reasons. 

To avoid the default assignment, memory can be saved for an axis that does not use plane compensation by assigning the value 1 to P-COMP-00061.

 

* composition of the default value: 101*101 =10201

This parameter is available as of CNC Build V3.3079.06

P-COMP-00008

Unit of the length entries

Description

This parameter defines the unit of the length / position entries.

Parameter

kw.crosscomp2.unit

Data type

BOOLEAN

Data range

0: Encoder increments

1: Metric (in 0.1 µm)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00009

Distance between interpolation points

Description

This parameter defines the distance between two interpolation points if both axes use an identical grid (P-COMP-000031(grid) = QUADRATIC).

Parameter

kw.crosscomp2.interval

Data type

UNS32

Data range

0 < interval < MAX(UNS32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

 

P-COMP-00010

Last index of master axis 1

Description

This parameter determines the last valid index in the table of master axis 1 (maximum value is 100). The table always starts with index 0.

Parameter

kw.crosscomp2.last_index_master1

Data type

SGN32

Data range

0 ≤ P-COMP-00010 <= 100

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

As of Build V3.1.3079.06, P-COMP-00010 is freely assignable. There is no upper limit. However, the condition of P-COMP-00061 must be complied with.

P-COMP-00010 * P-COMP-00011 <= P-COMP-00061

Attention:

If this parameter is re-interpreted, all the values in the compensation value table (P-COMP-00016) must be read in again.

P-COMP-00011

Last index of master axis 2

Description

This parameter determines the last valid index in the table of the two master axes (maximum 100 values). The table always starts with index 0.

Parameter

kw.crosscomp2.last_index_master2

Data type

SGN32

Data range

0 ≤ P-COMP-00011 <= 100

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

As of Build V3.1.3079.06, P-COMP-00011 is freely assignable. There is no upper limit. However, the condition of P-COMP-00061 must be complied with.

P-COMP-00010 * P-COMP-00011 <= P-COMP-00061

Attention:

If this parameter is re-interpreted, all the values in the compensation value table (P-COMP-00016) must be read in again.

P-COMP-00012

Start position of master axis 1

Description

This parameter determines the start position of master axis 1 in the compensation table.

Parameter

kw.crosscomp2.start_position_master1

Data type

SGN32

Data range

MIN(SGN32) ≤ start_position_master1 < MAX(SGN32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

 

P-COMP-00013

Start position of master axis 2

Description

This parameter determines the start position of master axis 2 in the compensation table.

Parameter

kw.crosscomp2.start_position_master2

Data type

SGN32

Data range

MIN(SGN32) ≤ start_position_master2 < MAX(SGN32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

 

P-COMP-00014

Logical axis number of the master axis 1

Description

This parameter defines the logical axis number of the first master axis.

Parameter

kw.crosscomp2.master1_ax_nr

Data type

UNS16

Data range

1 ≤ master1_ax_nr ≤ MAX (UNS16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00015

Logical axis number of the master axis 2

Description

This parameter defines the logical axis number of the second master axis.

Parameter

kw.crosscomp2.master2_ax_nr

Data type

UNS16

Data range

1 ≤ master2_ax_nr ≤ MAX (UNS16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00016

Compensation values for the slave axis

Description

This parameter defines the relative compensation values of the slave axis at interpolation points [j][i]. When indexing the interpolation points in the compensation list, the first index j refers to the second master axis.

Parameter

kw.crosscomp2.table[j][i].correction

Data type

SGN32

Data range

MIN(SGN32) ≤ correction < MAX(SGN32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

 

P-COMP-00027

Number of cycles for ‘smooth switching’

Description

This parameter determines the number of cycles for which plane compensation is activated/deactivated smoothly.

Parameter

kw.crosscomp2.n_cycles

Data type

UNS16

Data range

0 ≤ n_cycles ≤ 20 (maximum number of cycles for which cross compensation is activated/deactivated,
application-specific)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00030

Manual activation

Description

Plane compensation is automatically activated by the CNC if it selected in the axis parameters (P-AXIS-00174) and the required conditions are met (e.g. axis is homed).

If the parameter is set to value 1, plane compensation must be activated explicitly by an NC command (see [PROG//Selecting/deselecting axis compensations in the NC program]. In addition, compensation is deselected at the end of the NC program, at CNC reset and on axis release.

Parameter

kw.crosscomp2.manual_activation

Data type

BOOLEAN

Data range

0: Automatic activation

1: Manual activation in NC program

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00032

Distance between the interpolation points of the first master axis

Description

The parameter defines the interval between two interpolation points for the first master axis if both master axes use a different grid (P-COMP-00031(grid) = RECTANGULAR).

Parameter

kw.crosscomp2.interval1

Data type

UNS32

Data range

0 < interval1 < MAX(UNS32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

 

P-COMP-00033

Distance between the interpolation points on the second master axis

Description

The parameter defines the interval between two interpolation points for the first master axis if both master axes use a different grid (P-COMP-00031(grid) = RECTANGULAR).

Parameter

kw.crosscomp2.interval2

Data type

UNS32

Data range

0 < interval2 < MAX(UNS32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks