Description

P-AXIS-00047

Activation of cross compensation

Description

This parameter activates the cross compensation.

Parameter

lr_param.crosscomp

Data type

BOOLEAN

Data range

0/1

Axis types

T

Dimension

T: ----

 

Default value

0

Drive types

----

Remarks

 

P-COMP-00060

Maximum number of table entries for cross compensation

Description

This cross compensation parameter (FCT-C5) saves the memory space required for a particular number of table entries.

 

The size of the actually used compensation table is defined by `last_index` (P-COMP-00004) and `last_index` must be smaller than `max_points`.

Parameter

kw.crosscomp.max_points

Data type

UNS32

Data range

0 <= P-COMP-00060

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

1001

Remarks

The parameter value can no longer be changed after start-up or after lists are reloaded. Otherwise error ID 110639 is output.

 

If P-COMP-00060 is not specified (or assigned the value 0), the default value is assigned to P-COMP-00060 for downward compatibility reasons. 

To avoid the default assignment, memory can be saved for an axis that does not use cross compensation by assigning the value 1 to P-COMP-00060.

This parameter is available as of CNC Build V3.3079.06

P-COMP-00003

Unit of the length entries

Description

The parameter defines the unit to be used for the length entries of compensation values.

Parameter

kw.crosscomp.unit

Data type

BOOLEAN

Data range

0: Encoder increments

1: Metric (in 0.1 µm)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00004

Last index of compensation value table

Description

This parameter determines the last valid index in the table of the master axis. The table always starts with index 0

Parameter

kw.crosscomp.last_index

Data type

SGN32

Data range

0 ≤ last_index < P-COMP-00060

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

P-COMP-00060 is available as of Build V3.1.3079.06. The upper limit in previous CNC versions is 1000.

P-COMP-00005

Logical axis number of the master axis

Description

This parameter determines the logical number of the master axis whose command position is used to calculate the input variable of the compensation value table of the slave axis.

Parameter

kw.crosscomp.master_ax_nr

Data type

UNS16

Data range

1 ≤ master_ax_nr ≤ MAX (UNS16)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00026

Number of cycles for ‘smooth switching’

Description

This parameter determines the number of cycles for which cross compensation is activated/deactivated smoothly.

Parameter

kw.crosscomp.n_cycles

Data type

UNS16

Data range

0 ≤ n_cycles ≤ 20 (maximum number of cycles for which cross compensation is activated/deactivated,
application-specific)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00029

Manual activation

Description

Cross compensation is automatically activated by the CNC if it selected in the axis parameters (P-AXIS-00047) and the required conditions are met (e.g. axis is homed).

If the parameter is set to the value 1, cross compensation must be activated explicitly by an NC command (see [PROG//Selecting/deselecting axis compensations in the NC program]. In addition, compensation is deselected at the end of the NC program, at CNC reset and on axis release.

Parameter

kw.crosscomp.manual_activation

Data type

BOOLEAN

Data range

0: Automatic activation

1: Manual activation in NC program

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Remarks

 

P-COMP-00006

Interpolation point of the master axis

Description

This parameter determines the interpolation points of the master axis on which the slave axis has to be corrected.

Parameter

kw.crosscomp.table[i].setpoint

Data type

SGN32

Data range

MIN(SGN64-1023) ≤ setpoint < MAX(SGN64-1023)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

As of V3.1.3132.0 and/or V4.29.0, the data type is REAL64; in earlier versions SGN32. This also affects the related data range.

P-COMP-00007

Compensation values for the slave axis

Description

This parameter determines the relative compensation values for the slave axis at interpolation points 'i'.

Parameter

kw.crosscomp.table[i].correction

Data type

REAL64

Data range

MIN(SGN64-1023) ≤ correction < MAX(SGN64-1023)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks

As of V3.1.3132.0 and/or V4.29.0, the data type is REAL64; in earlier versions SGN32. This also affects the related data range.