VAL_ScopeRecStop

VAL_ScopeRecStop 1:

The function block VAL_ScopeRecStop stops a recording of robot data.

Syntax

Definition:

FUNCTION_BLOCK VAL_ScopeRecStop
VAR_INPUT
    Execute  : BOOL := FALSE;
END_VAR
VAR_OUTPUT
    Busy     : BOOL := FALSE;
    Done     : BOOL := FALSE;
    Error    : BOOL := FALSE;
    ErrorID  : UDINT := 0;
END_VAR
VAR_IN_OUT
    AxesGroup  : T_StaeubliRobot;
END_VAR

VAL_ScopeRecStop 2: Inputs

Name

Type

Description

Execute

BOOL

Rising edge triggers function execution

VAL_ScopeRecStop 3: Outputs

Name

Type

Description

Busy

BOOL

Set when function block is executing. Reset when Done or Error is set

Done

BOOL

This output is set when function block has terminated with success

Error

BOOL

This output is set when function block has terminated with error

ErrorID

UDINT

Error code

VAL_ScopeRecStop 4:/VAL_ScopeRecStop 5: Inputs/Outputs

Name

Type

Description

AxesGroup

T_StaeubliRobot

Data block for a robot